ABB 3 Pole Contactor, 30 A, 230 V ac Coil, A Line, 3NO, 7.5 kW
SKU: A16-30-10 220-230V 50Hz / 230-240V 60Hz
Specifications
CATEGORY:
PRODUCT BRAND:
PRODUCT NAME:
ABB 3 Pole Contactor, 30 A, 230 V ac Coil, A Line, 3NO, 7.5 kW
PRODUCT NUMBER:
A16-30-10 220-230V 50Hz / 230-240V 60Hz
AVAILABILITY:
On-Demand
DESCRIPTION
A16-30-10 220-230V 50Hz / 230-240V 60Hz
General Information
- Extended Product Type:
- A16-30-10 220-230V 50Hz / 230-240V 60Hz
- Product ID:
- 1SBL181001R8010
- EAN:
- 3471522050809
- Catalog Description:
- A16-30-10 220-230V 50Hz / 230-240V 60Hz Contactor
- Long Description:
- A16 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A… series 1-stack 3-pole contactors are of the block type design. – Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks – Control circuit: AC operated with laminated magnet circuit – Accessories: a wide range of accessories is available.
Ordering
- Minimum Order Quantity:
- 1 piece
- Customs Tariff Number:
- 85364900
- Replacement Product ID (NEW):
- 1SBL171001R8010
Popular Downloads
- Data Sheet, Technical Information:
- 1SBC100122C0202_Ch02
- Instructions and Manuals:
- FPTC407721P0001
Dimensions
- Product Net Width:
- 44 mm
- Product Net Depth / Length:
- 74 mm
- Product Net Height:
- 74 mm
- Product Net Weight:
- 0.34 kg
Technical
- Number of Main Contacts NO:
- 3
- Number of Main Contacts NC:
- 0
- Number of Auxiliary Contacts NO:
- 1
- Number of Auxiliary Contacts NC:
- 0
- Standards:
- Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1, EN 60 947-1 and amendment 2 to IEC 947-4-1
- Rated Operational Voltage:
- Auxiliary Circuit 690 V
Main Circuit 690 V
- Rated Frequency (f):
- Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith):
- acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 30 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
- Rated Operational Current AC-1 (Ie):
- (690 V) 40 °C 30 A
(690 V) 55 °C 27 A
(690 V) 70 °C 23 A
- Rated Operational Current AC-3 (Ie):
- (415 V) 55 °C 17 A
(440 V) 55 °C 16 A
(500 V) 55 °C 14 A
(690 V) 55 °C 10 A
(380 / 400 V) 55 °C 17 A
(220 / 230 / 240 V) 55 °C 17
- Rated Operational Power AC-3 (Pe):
- (415 V) 9 kW
(440 V) 9 kW
(500 V) 9 kW
(690 V) 9 kW
(380 / 400 V) 7.5 kW
(220 / 230 / 240 V) 4 kW
- Rated Operational Power AC-6b (Pe):
- (230 / 240 V) 40 °C, 50 / 60 Hz 7.5 kvar
(230 / 240 V) 55 °C, 50 / 60 Hz 7.5 kvar
(230 / 240 V) 70 °C, 50 / 60 Hz 6 kvar
(400 / 415 V) 40 °C, 50 / 60 Hz 12.5 kvar
(400 / 415 V) 70 °C, 50 / 60 Hz 10 kvar
(400 / 415 V) 55 °C, 50 / 60 Hz 12.5 kvar
(440 V) 40 °C, 50 / 60 Hz 14 kvar
(440 V) 55 °C, 50 / 60 Hz 14 kvar
(440 V) 70 °C, 50 / 60 Hz 10.5 kvar
(500 / 550 V), 40 °C, 50 / 60 Hz 15.5 kvar
(500 / 550 V) 55 °C, 50 / 60 Hz 15.5 kvar
(500 / 550 V) 70 °C, 50 / 60 Hz 12 kvar
(690 V) 40 °C, 50 / 60 Hz 21.5 kvar
(690 V) 55 °C, 50 / 60 Hz 21.5 kvar
(690 V) 70 °C, 50 / 60 Hz 16.5 kvar
- Rated Breaking Capacity AC-3:
- 8 x Ie AC-3
- Rated Making Capacity AC-3:
- 10 x Ie AC-3
- Rated Operational Current AC-15 (Ie):
- (500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A
- Short-Circuit Protective Devices:
- Auxiliary Circuit – gG Type Fuses 10 A
gG Type Fuses 32 A
- Rated Short-time Withstand Current Low Voltage (Icw):
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 140 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 30 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
for 0.1 s 140 A
for 1 s 100 A
- Maximum Breaking Capacity:
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
- Maximum Electrical Switching Frequency:
- (AC-1) 600 cycles per hour
(AC-2 / AC-4) 300 cycles per hour
(AC-3) 1200 cycles per hour
- Rated Operational Current DC-13 (Ie):
- (24 V) 6 / 144 A
(48 V) 2.8 / 134 A
(72 V) 2 / 144 W
(125 V) 1.1 / 138 W
(250 V) 0.55 / 138 W
- Rated Insulation Voltage (Ui):
- acc. to IEC 60947-4-1 1000 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
- Rated Impulse Withstand Voltage (Uimp):
- 8 kV
- Maximum Mechanical Switching Frequency:
- 3600 cycles per hour
- Rated Control Circuit Voltage (Uc):
- 50 Hz 220 … 230 V
60 Hz 230 … 240 V
- Coil Consumption:
- Average Holding Value 50 / 60 Hz 8 V·A
Average Pull-in Value 50 Hz 74 V·A
Average Pull-in Value 60 Hz 70 V·A
- Operate Time:
- Between Coil De-energization and NO Contact Opening 4 … 11 ms
Between Coil Energization and NO Contact Closing 10 … 26 ms
- Mounting on DIN Rail:
- TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
- Mounting by Screws (not supplied):
- 2 x M4 screws placed diagonally
- Connecting Capacity Main Circuit:
- Flexible with Cable End 0.75 … 2.5 mm²
Rigid Cable 1 … 4 mm²
- Connecting Capacity Auxiliary Circuit:
- Flexible with Cable End 0.75 … 2.5 mm²
Rigid Cable 1 … 4 mm²
- Degree of Protection:
- acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
- Connecting Terminals (delivered in open position) Main Poles:
- M 3.5 (+,-) pozidriv 2 screws with cable clamp
- Terminal Type:
- Screw Terminals
Technical UL/CSA
- General Use Rating UL/CSA:
- (600 V AC) 30 A
- Horsepower Rating UL/CSA:
- (200 … 208 V AC) Three Phase 5 hp
(220 … 240 V AC) Three Phase 5 hp
(440 … 480 V AC) Three Phase 10 hp
(550 … 600 V AC) Three Phase 15 hp
Environmental
- Ambient Air Temperature:
- Close to Contactor Fitted with Thermal O/L Relay -25 … 55 °C
Close to Contactor without Thermal O/L Relay (0.85 … 1.1 Uc) -40 … 55 °C
Close to Contactor without Thermal O/L Relay (Uc) -40 … 70 °C
Close to Contactor for Storage -60 … +80 °C
- Climatic Withstand:
- acc. to IEC 60068-2-30 and 60068-2-11 – UTE C 63-100 specification II
- Maximum Operating Altitude Permissible:
- Without Derating 3000 m
- Resistance to Shock acc. to IEC 60068-2-27:
- Closed, Shock Direction: B1 10 g
Open, Shock Direction: B1 5 g
Shock Direction: A 20 g
Shock Direction: B2 15 g
Shock Direction: C1 20 g
Shock Direction: C2 20 g
- RoHS Status:
- Following EU Directive 2011/65/EU
Certificates and Declarations
- BV Certificate:
- BV_2634H07559E0
- CB Certificate:
- CB_CN44759
- CCC Certificate:
- CCC_2018010304059156
CCC_2004010309130463
- CQC Certificate:
- CQC2013010304615753
CQC2018010304059156
CQC2004010309130463
- CSA Certificate:
- CSA_1041746
- Declaration of Conformity – CCC:
- 2020980304001607
2020980304001616
2020980304001229
- Declaration of Conformity – CE:
- 1SBD250801U1000
- Declaration of Conformity – UKCA:
- 1SBD250818U1000
- DNV Certificate:
- DNV-GL_TAE00000TX
- DNV GL Certificate:
- DNV-GL_TAE00000TX
- EAC Certificate:
- EAC_RU C-FR ME77 B03599
- LOVAG Certificate:
- LOVAG_FR97039
- LR Certificate:
- LRS_9830011E4
- RINA Certificate:
- RINA_ELE172319XG001
- RMRS Certificate:
- RMRS_0507015250
- UL Certificate:
- UL_20160205-E312527-10-2
- UL Listing Card:
- UL_E312527
Container Information
- Package Level 1 Units:
- 1 piece
- Package Level 1 Width:
- 78 mm
- Package Level 1 Depth / Length:
- 76 mm
- Package Level 1 Height:
- 47 mm
- Package Level 1 Gross Weight:
- 0.34 kg
- Package Level 1 EAN:
- 3471522050809
- Package Level 2 Units:
- box 63 piece
- Package Level 2 Width:
- 300 mm
- Package Level 2 Depth / Length:
- 245 mm
- Package Level 2 Height:
- 308 mm
- Package Level 2 Gross Weight:
- 21.42 kg
- Package Level 3 Units:
- 1220 piece
Classifications
- Object Classification Code:
- Q
- ETIM 4:
- EC000066 – Magnet contactor, AC-switching
- ETIM 5:
- EC000066 – Magnet contactor, AC-switching
- ETIM 6:
- EC000066 – Power contactor, AC switching
- ETIM 7:
- EC000066 – Power contactor, AC switching
- ETIM 8:
- EC000066 – Power contactor, AC switching
- eClass:
- V11.0 : 27371003
- UNSPSC:
- 39121529
- IDEA Granular Category Code (IGCC):
- 4756 >> Capacitor magnet contactor
- E-Number (Finland):
- 3709218
Item reviews
Only logged in customers who have purchased this product may leave a review.
Related products
-
ABB 3 Pole Contactor, 30 A, 230 V ac Coil, AF Range, 3NO, 7.5 kW
$1.00 Add to cart -
ABB CA5, 2NO/2NC (4), Auxiliary Contact, Front Mount, 6 A
$1.00 Add to cart -
ABB 2 Pole Contactor, 20 A, 230 V ac Coil, System M Pro, 2NO, 4 kW
$1.00 Add to cart -
ABB 3 Pole Contactor, 25 A, 230 V ac Coil, AF Range, 3NO, 4 kW
$1.00 Add to cart -
Auxiliary Contact,3 NO and 1 NC,Front Mounting,Screw Terminals,For Use With 100 K Contactors
$1.00 Add to cart
Reviews
There are no reviews yet.