ABB 4 Pole Contactor, 25 A, 230 V ac Coil, AF Range, 4NO, 4 kW
SKU: AF09-40-00-13
Specifications
CATEGORY:
PRODUCT BRAND:
PRODUCT NAME:
ABB 4 Pole Contactor, 25 A, 230 V ac Coil, AF Range, 4NO, 4 kW
PRODUCT NUMBER:
AF09-40-00-13
AVAILABILITY:
On-Demand
DESCRIPTION
AF09-40-00-13
General Information
- Extended Product Type:
- AF09-40-00-13
- Product ID:
- 1SBL137201R1300
- EAN:
- 3471523115033
- Catalog Description:
- AF09-40-00-13 100-250V50/60HZ-DC Contactor
- Long Description:
- The AF09-40-00-13 is a 4 pole – 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 4 kW / 400 V AC (AC-3) and switching power circuits up to 25 A (AC-1) or 25 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Ordering
- Minimum Order Quantity:
- 1 piece
- Customs Tariff Number:
- 85364900
Popular Downloads
- Instructions and Manuals:
- 1SBC101027M6801
- CAD Dimensional Drawing:
- 2CDC001079B0201
Dimensions
- Product Net Width:
- 45 mm
- Product Net Depth / Length:
- 77 mm
- Product Net Height:
- 86 mm
- Product Net Weight:
- 0.27 kg
Technical
- Number of Main Contacts NO:
- 4
- Number of Main Contacts NC:
- 0
- Number of Auxiliary Contacts NO:
- 0
- Number of Auxiliary Contacts NC:
- 0
- Standards:
- IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 60947-4-1
- Rated Operational Voltage:
- Main Circuit 690 V
- Rated Frequency (f):
- Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith):
- acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 A
- Rated Operational Current AC-1 (Ie):
- (690 V) 40 °C 25 A
(690 V) 60 °C 25 A
(690 V) 70 °C 22 A
- Rated Operational Current AC-3 (Ie):
- (415 V) 60 °C 9 A
(440 V) 60 °C 9 A
(500 V) 60 °C 9.5 A
(690 V) 60 °C 7 A
(380 / 400 V) 60 °C 9 A
(220 / 230 / 240 V) 60 °C 9 A
- Rated Operational Power AC-3 (Pe):
- (400 V) 4 kW
(415 V) 4 kW
(440 V) 4 kW
(500 V) 5.5 kW
(690 V) 5.5 kW
(380 / 400 V) 4 kW
(220 / 230 / 240 V) 2.2 kW
- Rated Short-time Withstand Current Low Voltage (Icw):
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
- Maximum Breaking Capacity:
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
- Maximum Electrical Switching Frequency:
- (AC-1) 600 cycles per hour
- Rated Operational Current DC-1 (Ie):
- (110 V) 1-Pole, 40 °C 10 A
(110 V) 1-Pole, 60 °C 10 A
(110 V) 1-Pole, 70 °C 10 A
(110 V) 2 Poles in Series, 40 °C 25 A
(110 V) 2 Poles in Series, 60 °C 25 A
(110 V) 2 Poles in Series, 70 °C 22 A
(110 V) 3 Poles in Series, 40 °C 25 A
(110 V) 3 Poles in Series, 60 °C 25 A
(110 V) 3 Poles in Series, 70 °C 22 A
(110 V) 4 Poles in Series, 40 °C 25 A
(110 V) 4 Poles in Series, 60 °C 25 A
(110 V) 4 Poles in Series, 70 °C 22 A
(220 V) 2 Poles in Series, 40 °C 10 A
(220 V) 2 Poles in Series, 60 °C 10 A
(220 V) 2 Poles in Series, 70 °C 10 A
(220 V) 3 Poles in Series, 40 °C 25 A
(220 V) 3 Poles in Series, 60 °C 25 A
(220 V) 3 Poles in Series, 70 °C 22 A
(220 V) 4 Poles in Series, 40 °C 25 A
(220 V) 4 Poles in Series, 60 °C 25 A
(220 V) 4 Poles in Series, 70 °C 22 A
(440 V) 4 Poles in Series, 40 °C 10 A
(440 V) 4 Poles in Series, 60 °C 10 A
(440 V) 4 Poles in Series, 70 °C 10 A
(72 V) 1-Pole, 40 °C 25 A
(72 V) 1-Pole, 60 °C 25 A
(72 V) 1-Pole, 70 °C 22 A
(72 V) 2 Poles in Series, 40 °C 25 A
(72 V) 2 Poles in Series, 60 °C 25 A
(72 V) 2 Poles in Series, 70 °C 22 A
(72 V) 3 Poles in Series, 40 °C 25 A
(72 V) 3 Poles in Series, 60 °C 25 A
(72 V) 3 Poles in Series, 70 °C 22 A
(72 V) 4 Poles in Series, 40 °C 25 A
(72 V) 4 Poles in Series, 60 °C 25 A
(72 V) 4 Poles in Series, 70 °C 22 A
- Rated Operational Current DC-3 (Ie):
- (110 V) 1-Pole, 40 °C 6 A
(110 V) 1-Pole, 60 °C 6 A
(110 V) 1-Pole, 70 °C 6 A
(110 V) 2 Poles in Series, 40 °C 25 A
(110 V) 2 Poles in Series, 60 °C 25 A
(110 V) 2 Poles in Series, 70 °C 22 A
(110 V) 3 Poles in Series, 40 °C 25 A
(110 V) 3 Poles in Series, 60 °C 25 A
(110 V) 3 Poles in Series, 70 °C 22 A
(110 V) 4 Poles in Series, 40 °C 25 A
(110 V) 4 Poles in Series, 60 °C 25 A
(110 V) 4 Poles in Series, 70 °C 22 A
(220 V) 2 Poles in Series, 40 °C 6 A
(220 V) 2 Poles in Series, 60 °C 6 A
(220 V) 2 Poles in Series, 70 °C 6 A
(220 V) 3 Poles in Series, 40 °C 25 A
(220 V) 3 Poles in Series, 60 °C 25 A
(220 V) 3 Poles in Series, 70 °C 22 A
(220 V) 4 Poles in Series, 40 °C 25 A
(220 V) 4 Poles in Series, 60 °C 25 A
(220 V) 4 Poles in Series, 70 °C 22 A
(440 V) 4 Poles in Series, 40 °C 6 A
(440 V) 4 Poles in Series, 60 °C 6 A
(440 V) 4 Poles in Series, 70 °C 6 A
(72 V) 1-Pole, 40 °C 25 A
(72 V) 1-Pole, 60 °C 25 A
(72 V) 1-Pole, 70 °C 22 A
(72 V) 2 Poles in Series, 40 °C 25 A
(72 V) 2 Poles in Series, 60 °C 25 A
(72 V) 2 Poles in Series, 70 °C 22 A
(72 V) 3 Poles in Series, 40 °C 25 A
(72 V) 3 Poles in Series, 60 °C 25 A
(72 V) 3 Poles in Series, 70 °C 22 A
(72 V) 4 Poles in Series, 40 °C 25 A
(72 V) 4 Poles in Series, 60 °C 25 A
(72 V) 4 Poles in Series, 70 °C 22 A
- Rated Operational Current DC-5 (Ie):
- (110 V) 1-Pole, 40 °C 4 A
(110 V) 1-Pole, 60 °C 4 A
(110 V) 1-Pole, 70 °C 4 A
(110 V) 2 Poles in Series, 40 °C 10 A
(110 V) 2 Poles in Series, 60 °C 10 A
(110 V) 2 Poles in Series, 70 °C 10 A
(110 V) 3 Poles in Series, 40 °C 25 A
(110 V) 3 Poles in Series, 60 °C 25 A
(110 V) 3 Poles in Series, 70 °C 22 A
(110 V) 4 Poles in Series, 40 °C 25 A
(110 V) 4 Poles in Series, 60 °C 25 A
(110 V) 4 Poles in Series, 70 °C 22 A
(220 V) 2 Poles in Series, 40 °C 4 A
(220 V) 2 Poles in Series, 60 °C 4 A
(220 V) 2 Poles in Series, 70 °C 4 A
(220 V) 3 Poles in Series, 40 °C 9 A
(220 V) 3 Poles in Series, 60 °C 9 A
(220 V) 3 Poles in Series, 70 °C 9 A
(220 V) 4 Poles in Series, 40 °C 10 A
(220 V) 4 Poles in Series, 60 °C 10 A
(220 V) 4 Poles in Series, 70 °C 10 A
(440 V) 4 Poles in Series, 40 °C 4 A
(440 V) 4 Poles in Series, 60 °C 4 A
(440 V) 4 Poles in Series, 70 °C 4 A
(72 V) 1-Pole, 40 °C 9 A
(72 V) 1-Pole, 60 °C 9 A
(72 V) 1-Pole, 70 °C 9 A
(72 V) 2 Poles in Series, 40 °C 25 A
(72 V) 2 Poles in Series, 60 °C 25 A
(72 V) 2 Poles in Series, 70 °C 22 A
(72 V) 3 Poles in Series, 40 °C 25 A
(72 V) 3 Poles in Series, 60 °C 25 A
(72 V) 3 Poles in Series, 70 °C 22 A
(72 V) 4 Poles in Series, 40 °C 25 A
(72 V) 4 Poles in Series, 60 °C 25 A
(72 V) 4 Poles in Series, 70 °C 22 A
- Rated Insulation Voltage (Ui):
- acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
- Rated Impulse Withstand Voltage (Uimp):
- 6 kV
- Maximum Mechanical Switching Frequency:
- 3600 cycles per hour
- Rated Control Circuit Voltage (Uc):
- 50 Hz 100 … 250 V
60 Hz 100 … 250 V
DC Operation 100 … 250 V
- Operate Time:
- Between Coil De-energization and NC Contact Closing 13 … 98 ms
Between Coil De-energization and NO Contact Opening 11 … 95 ms
Between Coil Energization and NC Contact Opening 38 … 90 ms
Between Coil Energization and NO Contact Closing 40 … 95 ms
- Mounting on DIN Rail:
- TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
- Mounting by Screws (not supplied):
- 2 x M4 screws placed diagonally
- Connecting Capacity Main Circuit:
- Flexible with Ferrule 1/2x 0.75 … 6 mm²
Flexible with Insulated Ferrule 1x 0.75 … 4 mm²
Flexible with Insulated Ferrule 2x 0.75 … 2.5 mm²
Rigid Solid 1/2x 1 … 4 mm²
Rigid Stranded 1/2x 1 … 6 mm²
- Connecting Capacity Auxiliary Circuit:
- Rigid Solid 1/2x 1 … 2.5 mm²
Rigid Stranded 1/2x 1 … 2.5 mm²
- Connecting Capacity Control Circuit:
- Flexible with Ferrule 1/2x 0.75 … 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 … 1.5 mm²
Rigid Solid 1/2x 1 … 2.5 mm²
Rigid Stranded 1/2x 1 … 2.5 mm²
- Wire Stripping Length:
- Control Circuit 10 mm
Main Circuit 10 mm
- Degree of Protection:
- acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
- Terminal Type:
- Screw Terminals
Technical UL/CSA
- Maximum Operating Voltage UL/CSA:
- Main Circuit 600 V
- General Use Rating UL/CSA:
- (600 V AC) 25 A
- Connecting Capacity Main Circuit UL/CSA:
- Rigid Solid 1/2x 16-10 AWG
Rigid Stranded 1/2x 16-10 AWG
- Connecting Capacity Auxiliary Circuit UL/CSA:
- Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
- Connecting Capacity Control Circuit UL/CSA:
- Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
- Tightening Torque UL/CSA:
- Control Circuit 11 in·lb
Main Circuit 13 in·lb
Environmental
- Ambient Air Temperature:
- Close to Contactor for Storage -60 … +80 °C
Near Contactor for Operation in Free Air -40 … 70 °C
- Climatic Withstand:
- Category B according to IEC 60947-1 Annex Q
- Maximum Operating Altitude Permissible:
- Without Derating 3000 m
- Resistance to Vibrations acc. to IEC 60068-2-6:
- 5 … 300 Hz 4 g closed position / 2 g open position
- Resistance to Shock acc. to IEC 60068-2-27:
- Closed, Shock Direction: B1 25 g
Open, Shock Direction: B1 5 g
Shock Direction: A 30 g
Shock Direction: B2 15 g
Shock Direction: C1 25 g
Shock Direction: C2 25 g
- RoHS Status:
- Following EU Directive 2011/65/EU
Certificates and Declarations
- ABS Certificate:
- ABS_20-2060694-PDA
- BV Certificate:
- BV_2634H24898C0
- CB Certificate:
- CB_SE-108879
- CCC Certificate:
- CCC_2010010304445624
- CQC Certificate:
- CQC2010010304445624
CQC2020010304298240
- Declaration of Conformity – CCC:
- 2020980304001253
2020980304001082
- Declaration of Conformity – CE:
- 1SBD250001U1000
- Declaration of Conformity – UKCA:
- 1SBD250032U1000
- DNV Certificate:
- DNV_TAE00001AF-4
- EAC Certificate:
- EAC_RU_FRME77B03447
- GOST Certificate:
- GOST_POCCFR.ME77.B07175.pdf
- KC Certificate:
- KC_HW02016-15007C
- LR Certificate:
- LRS_LR2002723TA-02
- RINA Certificate:
- RINA_ELE240318XG
- RMRS Certificate:
- RMRS_1802705280
- UL Certificate:
- UL-US-L319322-13-72119002-3
UL-CA-L319322-43-72119002-3
- UL Listing Card:
- UL_E319322
Container Information
- Package Level 1 Units:
- box 1 piece
- Package Level 1 Width:
- 87 mm
- Package Level 1 Depth / Length:
- 79 mm
- Package Level 1 Height:
- 47 mm
- Package Level 1 Gross Weight:
- 0.27 kg
- Package Level 1 EAN:
- 3471523115033
- Package Level 2 Units:
- box 27 piece
- Package Level 2 Width:
- 250 mm
- Package Level 2 Depth / Length:
- 300 mm
- Package Level 2 Height:
- 315 mm
- Package Level 2 Gross Weight:
- 14.58 kg
- Package Level 3 Units:
- 1296 piece
Classifications
- Object Classification Code:
- Q
- ETIM 4:
- EC000066 – Magnet contactor, AC-switching
- ETIM 5:
- EC000066 – Magnet contactor, AC-switching
- ETIM 6:
- EC000066 – Power contactor, AC switching
- ETIM 7:
- EC000066 – Power contactor, AC switching
- ETIM 8:
- EC000066 – Power contactor, AC switching
- eClass:
- V11.0 : 27371003
- UNSPSC:
- 39121529
- IDEA Granular Category Code (IGCC):
- 4758 >> Iec Contactors
- E-Number (Finland):
- 3706330
- E-Number (Sweden):
- 3211390
Item reviews
Only logged in customers who have purchased this product may leave a review.
Related products
-
AF Range TEF4 Series ON Delay Electronic Timer, NO/NC Contacts
$1.00 Add to cart -
ABB S2C, NO/NC (2), Auxiliary Contact, Side Mount, 1.5 A dc, 6 A ac
$1.00 Add to cart -
ABB CA4, NC (1), Auxiliary Contact, Front Mount, 6 A
$1.00 Add to cart -
ABB 3 Pole Contactor, 30 A, 230 V ac Coil, A Line, 3NO, 7.5 kW
$1.00 Add to cart -
100S-C 3P SAFETY RELAYS, 24 V DC, 23 A, 690 V AC
$1.00Rated 4.50 out of 5Add to cart
Reviews
There are no reviews yet.