    • AF30-30-00-11

      General Information

      • Extended Product Type:
        AF30-30-00-11
      • Product ID:
        1SBL277001R1100
      • EAN:
        3471523111219
      • Catalog Description:
        AF30-30-00-11 24-60V50/60HZ 20-60VDC Contactor
      • Long Description:
        The AF30-30-00-11 is a 3 pole – 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 15 kW / 400 V AC (AC-3) or 20 hp / 480 V UL and switching power circuits up to 50 A (AC-1) or 50 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

      Ordering

      • Minimum Order Quantity:
        1 piece
      • Customs Tariff Number:
        85364900

      Popular Downloads

      Dimensions

      • Product Net Width:
        45 mm
      • Product Net Depth / Length:
        86 mm
      • Product Net Height:
        86 mm
      • Product Net Weight:
        0.31 kg

      Technical

      • Number of Main Contacts NO:
        3
      • Number of Main Contacts NC:
        0
      • Number of Auxiliary Contacts NO:
        0
      • Number of Auxiliary Contacts NC:
        0
      • Standards:
        IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1
      • Rated Operational Voltage:
        Main Circuit 690 V
      • Rated Frequency (f):
        Control Circuit 50 / 60 Hz
        Main Circuit 50 / 60 Hz
      • Conventional Free-air Thermal Current (Ith):
        acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 50 A
      • Rated Operational Current AC-1 (Ie):
        (690 V) 40 °C 50 A
        (690 V) 60 °C 42 A
        (690 V) 70 °C 37 A
      • Rated Operational Current AC-3 (Ie):
        (415 V) 60 °C 32 A
        (440 V) 60 °C 32 A
        (500 V) 60 °C 28 A
        (690 V) 60 °C 21 A
        (380 / 400 V) 60 °C 32 A
        (220 / 230 / 240 V) 60 °C 33 A
      • Rated Operational Current AC-3e (Ie):
        (415 V) 60 °C 32 A
        (440 V) 60 °C 32 A
        (500 V) 60 °C 28 A
        (690 V) 60 °C 21 A
        (380 / 400 V) 60 °C 32 A
        (220 / 230 / 240 V) 60 °C 33 A
      • Rated Operational Power AC-3 (Pe):
        (400 V) 15 kW
        (415 V) 15 kW
        (440 V) 18.5 kW
        (500 V) 18.5 kW
        (690 V) 18.5 kW
        (380 / 400 V) 15 kW
        (220 / 230 / 240 V) 9 kW
      • Rated Operational Power AC-3e (Pe):
        (415 V) 15 kW
        (440 V) 18.5 kW
        (500 V) 18.5 kW
        (690 V) 18.5 kW
        (380 / 400 V) 15 kW
        (220 / 230 / 240 V) 9 kW
      • Rated Short-time Withstand Current Low Voltage (Icw):
        at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A
        at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A
        at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A
        at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A
        at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
      • Maximum Breaking Capacity:
        cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A
        cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
      • Maximum Electrical Switching Frequency:
        (AC-1) 600 cycles per hour
        (AC-2 / AC-4) 150 cycles per hour
        (AC-3) 1200 cycles per hour
      • Rated Operational Current DC-1 (Ie):
        (110 V) 2 Poles in Series, 40 °C 50 A
        (110 V) 2 Poles in Series, 60 °C 42 A
        (110 V) 2 Poles in Series, 70 °C 37 A
        (110 V) 3 Poles in Series, 40 °C 50 A
        (110 V) 3 Poles in Series, 60 °C 42 A
        (110 V) 3 Poles in Series, 70 °C 37 A
        (220 V) 3 Poles in Series, 40 °C 50 A
        (220 V) 3 Poles in Series, 60 °C 42 A
        (220 V) 3 Poles in Series, 70 °C 37 A
        (72 V) 1-Pole, 40 °C 50 A
        (72 V) 1-Pole, 60 °C 42 A
        (72 V) 1-Pole, 70 °C 37 A
        (72 V) 2 Poles in Series, 40 °C 50 A
        (72 V) 2 Poles in Series, 60 °C 42 A
        (72 V) 2 Poles in Series, 70 °C 37 A
        (72 V) 3 Poles in Series, 40 °C 50 A
        (72 V) 3 Poles in Series, 60 °C 42 A
        (72 V) 3 Poles in Series, 70 °C 37 A
      • Rated Operational Current DC-3 (Ie):
        (110 V) 2 Poles in Series, 40 °C 50 A
        (110 V) 2 Poles in Series, 60 °C 42 A
        (110 V) 2 Poles in Series, 70 °C 37 A
        (110 V) 3 Poles in Series, 40 °C 50 A
        (110 V) 3 Poles in Series, 60 °C 42 A
        (110 V) 3 Poles in Series, 70 °C 37 A
        (220 V) 3 Poles in Series, 40 °C 50 A
        (220 V) 3 Poles in Series, 60 °C 42 A
        (220 V) 3 Poles in Series, 70 °C 37 A
        (72 V) 1-Pole, 40 °C 50 A
        (72 V) 1-Pole, 60 °C 42 A
        (72 V) 1-Pole, 70 °C 37 A
        (72 V) 2 Poles in Series, 40 °C 50 A
        (72 V) 2 Poles in Series, 60 °C 42 A
        (72 V) 2 Poles in Series, 70 °C 37 A
        (72 V) 3 Poles in Series, 40 °C 50 A
        (72 V) 3 Poles in Series, 60 °C 42 A
        (72 V) 3 Poles in Series, 70 °C 37 A
      • Rated Operational Current DC-5 (Ie):
        (110 V) 2 Poles in Series, 40 °C 50 A
        (110 V) 2 Poles in Series, 60 °C 42 A
        (110 V) 2 Poles in Series, 70 °C 37 A
        (110 V) 3 Poles in Series, 40 °C 50 A
        (110 V) 3 Poles in Series, 60 °C 42 A
        (110 V) 3 Poles in Series, 70 °C 37 A
        (220 V) 3 Poles in Series, 40 °C 25 A
        (220 V) 3 Poles in Series, 60 °C 25 A
        (220 V) 3 Poles in Series, 70 °C 25 A
        (72 V) 1-Pole, 40 °C 25 A
        (72 V) 1-Pole, 60 °C 25 A
        (72 V) 1-Pole, 70 °C 25 A
        (72 V) 2 Poles in Series, 40 °C 50 A
        (72 V) 2 Poles in Series, 60 °C 42 A
        (72 V) 2 Poles in Series, 70 °C 37 A
        (72 V) 3 Poles in Series, 40 °C 50 A
        (72 V) 3 Poles in Series, 60 °C 42 A
        (72 V) 3 Poles in Series, 70 °C 37 A
      • Rated Insulation Voltage (Ui):
        acc. to IEC 60947-4-1 690 V
        acc. to UL/CSA 600 V
      • Rated Impulse Withstand Voltage (Uimp):
        6 kV
      • Maximum Mechanical Switching Frequency:
        3600 cycles per hour
      • Rated Control Circuit Voltage (Uc):
        50 Hz 24 … 60 V
        60 Hz 24 … 60 V
        DC Operation 20 … 60 V
      • Operate Time:
        Between Coil De-energization and NC Contact Closing 13 … 98 ms
        Between Coil De-energization and NO Contact Opening 11 … 95 ms
        Between Coil Energization and NC Contact Opening 38 … 90 ms
        Between Coil Energization and NO Contact Closing 40 … 95 ms
      • Mounting on DIN Rail:
        TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
        TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
      • Mounting by Screws (not supplied):
        2 x M4 screws placed diagonally
      • Connecting Capacity Main Circuit:
        Flexible with Ferrule 1/2x 1.5 … 10 mm²
        Flexible with Insulated Ferrule 1x 1.5 … 10 mm²
        Flexible with Insulated Ferrule 2x 1.5 … 4 mm²
        Rigid Solid 1/2x 2.5 … 4 mm²
        Rigid Stranded 1/2x 2.5 … 10 mm²
      • Connecting Capacity Control Circuit:
        Flexible with Ferrule 1/2x 0.75 … 2.5 mm²
        Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm²
        Flexible with Insulated Ferrule 2x 0.75 … 1.5 mm²
        Rigid Solid 1/2x 1 … 2.5 mm²
        Rigid Stranded 1/2x 1 … 2.5 mm²
      • Wire Stripping Length:
        Control Circuit 10 mm
        Main Circuit 14 mm
      • Degree of Protection:
        acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
        acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
      • Terminal Type:
        Screw Terminals

      Technical UL/CSA

      • Maximum Operating Voltage UL/CSA:
        Main Circuit 600 V
      • General Use Rating UL/CSA:
        (600 V AC) 50 A
      • Horsepower Rating UL/CSA:
        (120 V AC) Single Phase 2 hp
        (200 … 208 V AC) Three Phase 10 hp
        (220 … 240 V AC) Three Phase 10 hp
        (240 V AC) Single Phase 5 hp
        (440 … 480 V AC) Three Phase 20 hp
        (550 … 600 V AC) Three Phase 25 hp
      • Connecting Capacity Main Circuit UL/CSA:
        Rigid Solid 1/2x 14-10 AWG
        Rigid Stranded 1/2x 14-8 AWG
      • Connecting Capacity Control Circuit UL/CSA:
        Rigid Solid 1/2x 18-14 AWG
        Rigid Stranded 1/2x 18-14 AWG
      • Tightening Torque UL/CSA:
        Control Circuit 11 in·lb
        Main Circuit 22 in·lb

      Environmental

      • Ambient Air Temperature:
        Close to Contactor Fitted with Thermal O/L Relay -25 … 60 °C
        Close to Contactor without Thermal O/L Relay -40 … 70 °C
        Close to Contactor for Storage -60 … +80 °C
      • Climatic Withstand:
        Category B according to IEC 60947-1 Annex Q
      • Maximum Operating Altitude Permissible:
        Without Derating 3000 m
      • Resistance to Vibrations acc. to IEC 60068-2-6:
        5 … 300 Hz 4 g closed position / 2 g open position
      • Resistance to Shock acc. to IEC 60068-2-27:
        Closed, Shock Direction: B1 25 g
        Open, Shock Direction: B1 5 g
        Shock Direction: A 30 g
        Shock Direction: B2 15 g
        Shock Direction: C1 25 g
        Shock Direction: C2 25 g
      • RoHS Status:
        Following EU Directive 2011/65/EU

      Certificates and Declarations

      Container Information

      • Package Level 1 Units:
        box 1 piece
      • Package Level 1 Width:
        87 mm
      • Package Level 1 Depth / Length:
        87 mm
      • Package Level 1 Height:
        47 mm
      • Package Level 1 Gross Weight:
        0.31 kg
      • Package Level 1 EAN:
        3471523111219
      • Package Level 2 Units:
        box 21 piece
      • Package Level 2 Width:
        250 mm
      • Package Level 2 Depth / Length:
        300 mm
      • Package Level 2 Height:
        315 mm
      • Package Level 2 Gross Weight:
        13.95 kg
      • Package Level 3 Units:
        1080 piece

      Classifications

      • Object Classification Code:
        Q
      • ETIM 4:
        EC000066 – Magnet contactor, AC-switching
      • ETIM 5:
        EC000066 – Magnet contactor, AC-switching
      • ETIM 6:
        EC000066 – Power contactor, AC switching
      • ETIM 7:
        EC000066 – Power contactor, AC switching
      • ETIM 8:
        EC000066 – Power contactor, AC switching
      • eClass:
        V11.0 : 27371003
      • UNSPSC:
        39121529
      • IDEA Granular Category Code (IGCC):
        4758 >> Iec Contactors
      • E-Number (Finland):
        3705807
      • E-Number (Sweden):
        3211345