ABB AF30-30-00-11
SKU: AF30-30-00-11
Specifications
CATEGORY:
PRODUCT BRAND:
PRODUCT NAME:
ABB AF30-30-00-11
PRODUCT NUMBER:
AF30-30-00-11
AVAILABILITY:
On-Demand
DESCRIPTION
AF30-30-00-11
General Information
- Extended Product Type:
- AF30-30-00-11
- Product ID:
- 1SBL277001R1100
- EAN:
- 3471523111219
- Catalog Description:
- AF30-30-00-11 24-60V50/60HZ 20-60VDC Contactor
- Long Description:
- The AF30-30-00-11 is a 3 pole – 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 15 kW / 400 V AC (AC-3) or 20 hp / 480 V UL and switching power circuits up to 50 A (AC-1) or 50 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Ordering
- Minimum Order Quantity:
- 1 piece
- Customs Tariff Number:
- 85364900
Popular Downloads
- Instructions and Manuals:
- 1SBC101027M6801
- CAD Dimensional Drawing:
- 2CDC001079B0201
Dimensions
- Product Net Width:
- 45 mm
- Product Net Depth / Length:
- 86 mm
- Product Net Height:
- 86 mm
- Product Net Weight:
- 0.31 kg
Technical
- Number of Main Contacts NO:
- 3
- Number of Main Contacts NC:
- 0
- Number of Auxiliary Contacts NO:
- 0
- Number of Auxiliary Contacts NC:
- 0
- Standards:
- IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1
- Rated Operational Voltage:
- Main Circuit 690 V
- Rated Frequency (f):
- Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith):
- acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 50 A
- Rated Operational Current AC-1 (Ie):
- (690 V) 40 °C 50 A
(690 V) 60 °C 42 A
(690 V) 70 °C 37 A
- Rated Operational Current AC-3 (Ie):
- (415 V) 60 °C 32 A
(440 V) 60 °C 32 A
(500 V) 60 °C 28 A
(690 V) 60 °C 21 A
(380 / 400 V) 60 °C 32 A
(220 / 230 / 240 V) 60 °C 33 A
- Rated Operational Current AC-3e (Ie):
- (415 V) 60 °C 32 A
(440 V) 60 °C 32 A
(500 V) 60 °C 28 A
(690 V) 60 °C 21 A
(380 / 400 V) 60 °C 32 A
(220 / 230 / 240 V) 60 °C 33 A
- Rated Operational Power AC-3 (Pe):
- (400 V) 15 kW
(415 V) 15 kW
(440 V) 18.5 kW
(500 V) 18.5 kW
(690 V) 18.5 kW
(380 / 400 V) 15 kW
(220 / 230 / 240 V) 9 kW
- Rated Operational Power AC-3e (Pe):
- (415 V) 15 kW
(440 V) 18.5 kW
(500 V) 18.5 kW
(690 V) 18.5 kW
(380 / 400 V) 15 kW
(220 / 230 / 240 V) 9 kW
- Rated Short-time Withstand Current Low Voltage (Icw):
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
- Maximum Breaking Capacity:
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
- Maximum Electrical Switching Frequency:
- (AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
- Rated Operational Current DC-1 (Ie):
- (110 V) 2 Poles in Series, 40 °C 50 A
(110 V) 2 Poles in Series, 60 °C 42 A
(110 V) 2 Poles in Series, 70 °C 37 A
(110 V) 3 Poles in Series, 40 °C 50 A
(110 V) 3 Poles in Series, 60 °C 42 A
(110 V) 3 Poles in Series, 70 °C 37 A
(220 V) 3 Poles in Series, 40 °C 50 A
(220 V) 3 Poles in Series, 60 °C 42 A
(220 V) 3 Poles in Series, 70 °C 37 A
(72 V) 1-Pole, 40 °C 50 A
(72 V) 1-Pole, 60 °C 42 A
(72 V) 1-Pole, 70 °C 37 A
(72 V) 2 Poles in Series, 40 °C 50 A
(72 V) 2 Poles in Series, 60 °C 42 A
(72 V) 2 Poles in Series, 70 °C 37 A
(72 V) 3 Poles in Series, 40 °C 50 A
(72 V) 3 Poles in Series, 60 °C 42 A
(72 V) 3 Poles in Series, 70 °C 37 A
- Rated Operational Current DC-3 (Ie):
- (110 V) 2 Poles in Series, 40 °C 50 A
(110 V) 2 Poles in Series, 60 °C 42 A
(110 V) 2 Poles in Series, 70 °C 37 A
(110 V) 3 Poles in Series, 40 °C 50 A
(110 V) 3 Poles in Series, 60 °C 42 A
(110 V) 3 Poles in Series, 70 °C 37 A
(220 V) 3 Poles in Series, 40 °C 50 A
(220 V) 3 Poles in Series, 60 °C 42 A
(220 V) 3 Poles in Series, 70 °C 37 A
(72 V) 1-Pole, 40 °C 50 A
(72 V) 1-Pole, 60 °C 42 A
(72 V) 1-Pole, 70 °C 37 A
(72 V) 2 Poles in Series, 40 °C 50 A
(72 V) 2 Poles in Series, 60 °C 42 A
(72 V) 2 Poles in Series, 70 °C 37 A
(72 V) 3 Poles in Series, 40 °C 50 A
(72 V) 3 Poles in Series, 60 °C 42 A
(72 V) 3 Poles in Series, 70 °C 37 A
- Rated Operational Current DC-5 (Ie):
- (110 V) 2 Poles in Series, 40 °C 50 A
(110 V) 2 Poles in Series, 60 °C 42 A
(110 V) 2 Poles in Series, 70 °C 37 A
(110 V) 3 Poles in Series, 40 °C 50 A
(110 V) 3 Poles in Series, 60 °C 42 A
(110 V) 3 Poles in Series, 70 °C 37 A
(220 V) 3 Poles in Series, 40 °C 25 A
(220 V) 3 Poles in Series, 60 °C 25 A
(220 V) 3 Poles in Series, 70 °C 25 A
(72 V) 1-Pole, 40 °C 25 A
(72 V) 1-Pole, 60 °C 25 A
(72 V) 1-Pole, 70 °C 25 A
(72 V) 2 Poles in Series, 40 °C 50 A
(72 V) 2 Poles in Series, 60 °C 42 A
(72 V) 2 Poles in Series, 70 °C 37 A
(72 V) 3 Poles in Series, 40 °C 50 A
(72 V) 3 Poles in Series, 60 °C 42 A
(72 V) 3 Poles in Series, 70 °C 37 A
- Rated Insulation Voltage (Ui):
- acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
- Rated Impulse Withstand Voltage (Uimp):
- 6 kV
- Maximum Mechanical Switching Frequency:
- 3600 cycles per hour
- Rated Control Circuit Voltage (Uc):
- 50 Hz 24 … 60 V
60 Hz 24 … 60 V
DC Operation 20 … 60 V
- Operate Time:
- Between Coil De-energization and NC Contact Closing 13 … 98 ms
Between Coil De-energization and NO Contact Opening 11 … 95 ms
Between Coil Energization and NC Contact Opening 38 … 90 ms
Between Coil Energization and NO Contact Closing 40 … 95 ms
- Mounting on DIN Rail:
- TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
- Mounting by Screws (not supplied):
- 2 x M4 screws placed diagonally
- Connecting Capacity Main Circuit:
- Flexible with Ferrule 1/2x 1.5 … 10 mm²
Flexible with Insulated Ferrule 1x 1.5 … 10 mm²
Flexible with Insulated Ferrule 2x 1.5 … 4 mm²
Rigid Solid 1/2x 2.5 … 4 mm²
Rigid Stranded 1/2x 2.5 … 10 mm²
- Connecting Capacity Control Circuit:
- Flexible with Ferrule 1/2x 0.75 … 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 … 1.5 mm²
Rigid Solid 1/2x 1 … 2.5 mm²
Rigid Stranded 1/2x 1 … 2.5 mm²
- Wire Stripping Length:
- Control Circuit 10 mm
Main Circuit 14 mm
- Degree of Protection:
- acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
- Terminal Type:
- Screw Terminals
Technical UL/CSA
- Maximum Operating Voltage UL/CSA:
- Main Circuit 600 V
- General Use Rating UL/CSA:
- (600 V AC) 50 A
- Horsepower Rating UL/CSA:
- (120 V AC) Single Phase 2 hp
(200 … 208 V AC) Three Phase 10 hp
(220 … 240 V AC) Three Phase 10 hp
(240 V AC) Single Phase 5 hp
(440 … 480 V AC) Three Phase 20 hp
(550 … 600 V AC) Three Phase 25 hp
- Connecting Capacity Main Circuit UL/CSA:
- Rigid Solid 1/2x 14-10 AWG
Rigid Stranded 1/2x 14-8 AWG
- Connecting Capacity Control Circuit UL/CSA:
- Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
- Tightening Torque UL/CSA:
- Control Circuit 11 in·lb
Main Circuit 22 in·lb
Environmental
- Ambient Air Temperature:
- Close to Contactor Fitted with Thermal O/L Relay -25 … 60 °C
Close to Contactor without Thermal O/L Relay -40 … 70 °C
Close to Contactor for Storage -60 … +80 °C
- Climatic Withstand:
- Category B according to IEC 60947-1 Annex Q
- Maximum Operating Altitude Permissible:
- Without Derating 3000 m
- Resistance to Vibrations acc. to IEC 60068-2-6:
- 5 … 300 Hz 4 g closed position / 2 g open position
- Resistance to Shock acc. to IEC 60068-2-27:
- Closed, Shock Direction: B1 25 g
Open, Shock Direction: B1 5 g
Shock Direction: A 30 g
Shock Direction: B2 15 g
Shock Direction: C1 25 g
Shock Direction: C2 25 g
- RoHS Status:
- Following EU Directive 2011/65/EU
Certificates and Declarations
- ABS Certificate:
- ABS_20-2060694-PDA
- BV Certificate:
- BV_2634H24898C0
- CB Certificate:
- CB_SE-96552M1
- CCC Certificate:
- CCC_2010010304445623
- CQC Certificate:
- CQC2010010304445623
CQC2020010304294316
- Declaration of Conformity – CCC:
- 2020980304001254
2020980304001052
- Declaration of Conformity – CE:
- 1SBD250000U1000
- Declaration of Conformity – UKCA:
- 1SBD250031U1000
- DNV Certificate:
- DNV_TAE00001AF-4
- EAC Certificate:
- EAC_RU_FRME77B03447
- GOST Certificate:
- GOST_POCCFR.ME77.B07175.pdf
- KC Certificate:
- KC_HW02016-15001C
- LR Certificate:
- LRS_LR2002723TA-02
- RINA Certificate:
- RINA_ELE240318XG
- RMRS Certificate:
- RMRS_1802705280
- UL Certificate:
- UL-US-2150887-5
UL-CA-2142658-5
- UL Listing Card:
- E312527
Container Information
- Package Level 1 Units:
- box 1 piece
- Package Level 1 Width:
- 87 mm
- Package Level 1 Depth / Length:
- 87 mm
- Package Level 1 Height:
- 47 mm
- Package Level 1 Gross Weight:
- 0.31 kg
- Package Level 1 EAN:
- 3471523111219
- Package Level 2 Units:
- box 21 piece
- Package Level 2 Width:
- 250 mm
- Package Level 2 Depth / Length:
- 300 mm
- Package Level 2 Height:
- 315 mm
- Package Level 2 Gross Weight:
- 13.95 kg
- Package Level 3 Units:
- 1080 piece
Classifications
- Object Classification Code:
- Q
- ETIM 4:
- EC000066 – Magnet contactor, AC-switching
- ETIM 5:
- EC000066 – Magnet contactor, AC-switching
- ETIM 6:
- EC000066 – Power contactor, AC switching
- ETIM 7:
- EC000066 – Power contactor, AC switching
- ETIM 8:
- EC000066 – Power contactor, AC switching
- eClass:
- V11.0 : 27371003
- UNSPSC:
- 39121529
- IDEA Granular Category Code (IGCC):
- 4758 >> Iec Contactors
- E-Number (Finland):
- 3705807
- E-Number (Sweden):
- 3211345
Item reviews
Only logged in customers who have purchased this product may leave a review.
Related products
-
ABB 3 Pole Contactor, 28 A, 24 V ac/dc Coil, AF Range, 3NO, 5.5 kW
$1.00 Add to cart -
ABB CA4, NC (1), Auxiliary Contact, Front Mount, 6 A
$1.00 Add to cart -
Auxiliary Contact,3 NO and 1 NC,Front Mounting,Screw Terminals,For Use With 100 K Contactors
$1.00 Add to cart -
ABB DISCONNECTOR SWITCH OT40F6
$1.00 Add to cart -
ABB 1SBL371001R8100 AC OPERATED AUXILARY CONTACTOR-24V AC, 3P
$1.00 Add to cart
Reviews
There are no reviews yet.