Multiple Operating Modes and Multiple Time Ranges. DIN 48 x 48-mm Multifunctional Timer.

SKU: H3CR-A

Specifications

CATEGORY: ​
PRODUCT BRAND: ​
PRODUCT NAME: ​
Multiple Operating Modes and Multiple Time Ranges. DIN 48 x 48-mm Multifunctional Timer.
PRODUCT NUMBER:
H3CR-A
AVAILABILITY: ​
On-Demand

DESCRIPTION

• A wide AC/DC power supply range greatly reduces the number of timer models kept in stock.

• A wide range of applications with multiple operating modes, eight modes for 11-pin models and five modes for 8-pin models.

• Ecological design with reduced current consumption.

• Easy sequence checking with instantaneous outputs for a zero set value.

• Length of 75 mm or less when panel-mounted with a P3G-08 Socket (H3CR-A8E, 100 to 240 VAC, 100 to 125 VDC)

• PNP input models available.

• Standards: UL, CSA, NK, LR, CCC, EN 61812-1, and CE Marking.

H3CR-A Lineup 1

11-pin Models

 

OutputSupply voltageInput typeTime rangeOperating mode *2Model *1
Contact100 to 240 VAC (50/60 Hz)/
100 to 125 VDC
No-voltage
input
0.05 s to 300 hEight multi-modes:
A, B, B2, C, D, E, G, J
H3CR-A
24 to 48 VAC (50/60 Hz)/
12 to 48 VDC
100 to 240 VAC (50/60 Hz)/
100 to 125 VDC
Voltage inputEight multi-modes:
A, B, B2, C, D, E, G, J
H3CR-AP
24 to 48 VAC (50/60 Hz)/
12 to 48 VDC
100 to 240 VAC (50/60 Hz)/
100 to 125 VDC
No-voltage
input
0.1 s to 600 hH3CR-A-301
24 to 48 VAC (50/60 Hz)/
12 to 48 VDC
Transistor
(Photocoupler)
24 to 48 VAC (50/60 Hz)/
12 to 48 VDC
0.05 s to 300 hH3CR-AS

 

8-pin Models

 

OutputSupply voltageInput typeTime rangeOperating mode *2Model *1
Contact100 to 240 VAC (50/60 Hz)/
100 to 125 VDC
No-input
available
0.05 s to 300 hFive multi-modes:
A, B, B2, E, J
(Power supply start)
H3CR-A8
24 to 48 VAC (50/60 Hz)/
12 to 48 VDC
100 to 240 VAC (50/60 Hz)/
100 to 125 VDC
0.1 s to 600 hH3CR-A8-301
24 to 48 VAC (50/60 Hz)/
12 to 48 VDC
Transistor
(Photocoupler)
24 to 48 VAC (50/60 Hz)/
12 to 48 VDC
0.05 s to 300 hH3CR-A8S
Time-limit contact
and instantaneous
contact
100 to 240 VAC (50/60 Hz)/
100 to 125 VDC
H3CR-A8E
24 to 48 VAC/VDC (50/60 Hz)

 

Accessories (Order Separately)

Adapter, Protective Cover, Hold down Clip, Setting Ring and Panel Cover

 

Name/specificationsModels
Flush Mounting AdapterY92F-30
Y92F-73 *1
Y92F-74 *1
Y92F-38
Protective CoverY92A-48B *2
Hold-down Clip (Sold in sets of two)For PF085A SocketY92H-8
For PL08 or PL11 SocketsY92H-7
Setting Ring AY92S-27 *3
Setting Ring B and CY92S-28 *3
Panel CoverLight gray (5Y7/1)Y92P-48GL *4
Black (N1.5)Y92P-48GB *4

 

 

*1. The Y92A-48B Protective Cover and the Y92P-48G[] Panel Cover can not be used at the same time with the Y92F-73/
-74 Flush Mounting Adapter.
*2. The Y92A-48B Protective Cover is made from hard plastic. Remove the Protective Cover to change to set value. The
Y92F-73/-74 Flush Mounting Adapter and the Y92P-48G[] Panel Cover cannot be used at the same time with Y92A-
48B Protective Cover.
*3. The Y92S-27/-28 Setting Ring cannot be used alone. It must be used together with the Y92P-48G[] Panel Cover.
*4. The Y92A-48B Protective Cover and the Y92F-73/-74 Flush Mounting Adapter cannot be used at the same time with the
Y92P-48G[] Panel Cover.

 

Sockets

 

TimerRound Sockets
PinConnectionTerminalModels
11-pinFront ConnectingDIN track mountingP2CF-11
DIN track mounting (Finger-safe type)P2CF-11-E
Back ConnectingScrew terminalP3GA-11
Solder terminalPL11
Wrapping terminalPL11-Q
PCB terminalPLE11-0
8-pinFront ConnectingDIN track mountingP2CF-08
DIN track mounting (Finger-safe type)P2CF-08-E
DIN track mountingPF085A
Back ConnectingScrew terminalP3G-08
Solder terminalPL08
Wrapping terminalPL08-Q
PCB terminalPLE08-0

 

 

Note: 1. The P2CF-[][]-E has a finger-protection structure. Round crimp terminals cannot be used. Use forked crimp
terminals.
2. The P3GA-11 and P3G-08 Socket can be used together with the Y92A-48G Terminal Cover to implement finger
protection.
3. For details, refer to your OMRON website.

 

Terminal Cover

 

ApplicationModelRemarks
For back connecting socketY92A-48GFor P3G-08 and P3GA-11

 

General

 

ItemH3CR-A/-AS/-A-301H3CR-APH3CR-A8/-A8S/-A8-301H3CR-A8E
Operating modeA: ON-delay
B: Flicker OFF start
B2: Flicker ON start
C: Signal ON/OFF-delay
D: Signal OFF-delay
E: Interval
G: Signal ON/OFF-delay
J: One-shot
A: ON-delay (power supply start)
B: Flicker OFF start (power supply start)
B2: Flicker ON start (power supply start)
E: Interval (power supply start)
J: One-shot (power supply start)
Pin type11-pin8-pin
Input typeNo-voltage inputVoltage input
Time-limit output typeH3CR-A/-A8/-AP/-A-301/-A8-301: Relay output (DPDT)
H3CR-AS/-A8S: Transistor output (NPN/PNP universal) *1
Relay output
(SPDT)
Instantaneous output typeRelay output
(SPDT)
Mounting methodDIN track mounting, surface mounting, and flush mounting
Approved standardsUL508, CSA C22.2 No.14, NK, Lloyds, CCC: GB/T 14048.5 *2
Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2.
Output category according to EN60947-5-1 for Timers with Contact Outputs.
Output category according to EN60947-5-2 for Timers with Transistor Outputs.

 

 

*1 The internal circuits are optically isolated from the output. This enables universal application as NPN or PNP transistor.
For details, refer to your OMRON website.
*2 CCC certification requirements

 

 

Recommended fuseContact Output: 0216005 (250 VAC, 5 A), manufactured by Littelfuse
Transistor Output: 0216.100 (250 VAC, 100 mA) manufactured by Littelfuse
Rated operating voltage Ue
Rated operating current Ie
Contact Output:
AC-15: Ue: 250 VAC, Ie: 3 A
AC-13: Ue: 250 VAC, Ie: 5 A
DC-13: Ue: 30 VDC, Ie: 0.5 A
Transistor Output:
DC-13: Ue: 30 VDC, Ie: 0.1 A
Rated insulation voltage250 V
Rated impulse withstand voltage
(altitude: 2,000 m max.)
4 kV (at 240 VAC)
Conditional short-circuit current1000 A

 

Time Ranges

 

Note: When the time setting knob is turned below “0” until the point where the time setting knob stops, the output will
operate instantaneously at all time range settings.
For details, refer to your OMRON website.

 

Standard (0.05-s to 300-h) Models

 

Time units (sec)×10 s (10 sec)min (min)×10 min (10 min)h (hrs)×10 h (10 hrs)
Full scale
setting
1.20.05 to 1.21.2 to 120.12 to 1.21.2 to 120.12 to 1.21.2 to 12
30.3 to 33 to 300.3 to 33 to 300.3 to 33 to 30
121.2 to 1212 to 1201.2 to 1212 to 1201.2 to 1212 to 120
303 to 3030 to 3003 to 3030 to 3003 to 3030 to 300

 

Double (0.1-s to 600-h) Models

 

Time units (sec)×10 s (10 sec)min (min)×10 min (10 min)h (hrs)×10 h (10 hrs)
Full scale
setting
2.40.1 to 2.42.4 to 240.24 to 2.42.4 to 240.24 to 2.42.4 to 24
60.6 to 66 to 600.6 to 66 to 600.6 to 66 to 60
242.4 to 2424 to 2402.4 to 2424 to 2402.4 to 2424 to 240
606 to 6060 to 6006 to 6060 to 6006 to 6060 to 600

 

Ratings

 

Rated supply voltage
*1 *2 *5
100 to 240 VAC (50/60 Hz)/100 to 125 VDC, 24 to 48 VAC (50/60 Hz)/12 to
48 VDC (24 to 48 VAC/VDC for H3CR-A8E) *3
Operating voltage range85% to 110% of rated voltage (90% to 110% at 12 to 48 VDC)
Power resetMinimum power-opening time: 0.1 s
Input *6No-voltage Input
ON impedance: 1 kΩ max.
ON residual voltage: 1 V max.
OFF impedance: 100 kΩ min.
Voltage Input
Max. permissible capacitance between inputs lines (terminals 6 and 7): 1,200 pF
Load connectable in parallel with inputs (terminals 6 and 7).
100 to 240 VAC/100 to 125 VDC
High (logic) level: 85 to 264 VAC/85 to 137.5 VDC
Low (logic) level: 0 to 10 VAC/0 to 10 VDC
24 to 48 VAC/12 to 48 VDC
High (logic) level: 20.4 to 52.8 VAC/10.8 to 52.8 VDC
Low (logic) level: 0 to 2.4 VAC/0 to 1.2 VDC
Power consumptionH3CR-A/-A8
100 to 240 VAC/100 to 125 VDC (When at 240 VAC, 60 Hz)
Relay ON: approx. 2.0 VA (1.6 W), Relay OFF: approx. 1.3 VA (1.1 W)
24 to 48 VAC/12 to 48 VDC (When at 24 VDC)
Relay ON: approx. 0.8 W, Relay OFF: approx. 0.2 W
H3CR-AP *3
100 to 240 VAC/100 to 125 VDC (When at 240 VAC, 60 Hz)
Relay ON: approx. 2.5 VA (2.2 W) *4, Relay OFF: approx. 1.8 VA (1.7 W) *4
24 to 48 VAC/12 to 48 VDC (When at 24 VDC)
Relay ON: approx. 0.9 W *4, Relay OFF: approx. 0.3 W *4
H3CR-A8E
100 to 240 VAC/100 to 125 VDC (When at 240 VAC, 60 Hz)
Relay ON/OFF: approx. 2 VA (0.9 W)
24 to 48 VAC/VDC (When at 24 VDC)
Relay ON/OFF: approx. 0.9 W
H3CR-AS/-A8S
24 to 48 VAC/12 to 48 VDC (When at 24 VDC)
Output ON: 0.3 W, Output OFF: 0.2 W
Control outputsModels with Contact Outputs
H3CR-A/-A8/-AP
5A at 250 VAC/30 VDC, 0.15A at 125 VDC, resistive load (cosφ = 1)
Minimum applied load: 10mA at 5 VDC (failure level: P reference value)
Contact materials: Ag-alloy
H3CR-A8E
5A at 250 VAC/30 VDC, 0.15A at 125 VDC, resistive load (cosφ = 1)
Minimum applied load: 10mA at 5 VDC (failure level: P reference value)
Contact materials: AgSnIn
Transistor output: Open collector(NPN/PNP)
H3CR-AS/-A8S
100 mA max at 30 VDC max., residual voltage: 2 VDC max.

 

 

*1. DC ripple rate: 20% max. (A single-phase, full-wave-rectification power supply can be used).
*2. Do not use an inverter output as the power supply. Refer to your OMRON website for details.
*3. Models with 24-to-48-VAC or 12-to-48-VDC power supply have inrush current. Caution is thus required when turning
ON and OFF power to the Timer with a non-contact output from a device such as a sensor. (Models with an inrush
current of approximately 50 mA and a 24-VDC power supply are available (the H3CR-A-302 and H3CR-A8-302).)
For details, consult your OMRON sales representative.
*4. The values are for when the terminals 2 and 7 and terminals 10 and 6 are short-circuited, and include the
consumption current of the input circuit.
*5. Refer to your OMRON website when using the Timer together with a 2-wire AC proximity sensor.
*6. For details, see Input Connections: No-voltage Input Signal Levels on Catalog, and Input Connections: Voltage Input
Signal Levels on Catalog.

 

Characteristics

 

Accuracy of operating
time
±0.2% FS max. (±0.2%±10 ms max. in a range of 1.2 s or 3 s)
Setting error±5% FS ±50 ms *1
Reset timeMin. power-opening time: 0.1 s max.
Min. pulse width: 0.05 s (H3CR-A/-AS)
Reset voltage10% max. of rated supply voltage
Influence of voltage *2±0.2% FS max. (±0.2%±10 ms max. in a range of 1.2 s or 3 s)
Influence of temperature±1% FS max. (±1%±10 ms max. in a range of 1.2 s or 3 s)
Insulation resistance100 MΩ min. (at 500 VDC)
Dielectric strength2,000 VAC (1,000 VAC for H3CR-A[]S), 50/60 Hz for 1 min (between current-carrying
metal parts and exposed non-current-carrying metal parts)
2,000 VAC (1,000 VAC for H3CR-A[]S), 50/60 Hz for 1 min (between control output
terminals and operating circuit)
2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
2,000 VAC, 50/60 Hz for 1 min (between input and control output terminals and
operation circuit) for H3CR-AP
Impulse withstand
voltage
5 kV (between power terminals) for 100 to 240 VAC/100 to 125 VDC, 1 kV for 24 to 48
VAC/12 to 48 VDC
5 kV (between current-carrying terminal and exposed non-current-carrying metal
parts) for 100 to 240 VAC/100 to 125 VDC, 1.5 kV for 24 to 48 VAC/12 to 48 VDC and
24 to 48 VAC/VDC
Noise immunity±1.5 kV (between power terminals) and ±600 V (between no-voltage input terminals),
square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Static immunityMalfunction: 8 kV
Destruction: 15 kV
Vibration resistanceDestruction: 10 to 55 Hz with 0.75-mm single amplitude each in 3 directions for 2 hours
each
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude each in 3 directions for 10
minutes each
Shock resistanceDestruction: 1,000 m/s2 3 times each in 6 directions
Malfunction: 100 m/s2 3 times each in 6 directions
Ambient temperatureOperating: -10°C to 55°C (with no icing)
Storage: -25°C to 65°C (with no icing)
Ambient humidityOperating: 35% to 85%
Life expectancy *4Mechanical: 20,000,000 operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800
operations/h) *3
EMC(EMI) EN61812-1
Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
(EMS) EN61812-1
Immunity ESD: IEC61000-4-2
Immunity RF-interference: IEC61000-4-3
Immunity Burst: IEC61000-4-4
Immunity Surge: IEC61000-4-5
Immunity Conducted Disturbance: IEC61000-4-6
Immunity Voltage Dip/Interruption: IEC61000-4-11
Case colorLight gray (Munsell 5Y7/1)
Degree of protectionIP40 (panel surface)
WeightApprox. 90 g

 

*1. The value is ±5% FS +100 ms to −0 ms max. when the C, D, or G mode signal of the H3CR-AP is OFF.
*2. The influence of voltage of the H3CR-A8E (24 to 48 VAC/12 to 48 VDC) is ±2.0% FS max. with a single-phase power
supply with fullwave rectification.
*3. Refer to the Life-test Curve (Reference).
*4. Contact output only.

Life-test Curve (Reference)

H3CR-A Specifications 11

Reference:
A maximum current of 0.15 A can be switched at 125 VDC (cosφ = 1) and a maximum current of 0.1A can be switched at 125V DC and L/R = 7ms.
In both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC (failure level: P).

PRODUCT CATALOG: ​

Item reviews

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.