DESCRIPTION

Easier to Read

Character Height: 12 mm [Large Characters]

The larger characters and wider viewing angle join a bright display for easy reading even in well-lit locations.

H7CX-A Features 2

We increased the number of display segments to make setting parameters even easier.

H7CX-A Features 3

Orange Added to Switchable Display Colors to Readily Show the Output Status [Status Monitoring]

Using Green When Output Is OFF Using Orange When Output Is ON
*Display colors can be switched only on models with terminal blocks.

H7CX-A Features 4

Save Space

A Shorter Body [Make Thinner Panels]

The shorter body enables mounting in thin control panels.

H7CX-A Features 6

Models with terminal blocks for 12 to 24 VDC. (Shortest Body)

At only 59 mm, the shortest body for any industrial counter.

Models with terminal blocks for 100 to 240 VAC. (Shortest Body)

 

At only 78 mm, the shortest body for any industrial counter that isolates the power supply and input circuits.

*Models with Sockets: 63.7 mm (case dimension)

The above claims apply to counters with a maximum ambient temperature of 55 ºC.
According to OMRON investigations June 2009.

 

Safe and Reliable

Setting Upper Limit [Prevent Unexpected Operation]

Restricting the set time help prevent incorrect settings.

Output ON Count Alarm Indication [Service Life Notification]

The number of times that the control output turns ON is counted and an alarm is displayed when a preset count is exceeded.

More Complete Lineup

Twin Counter Mode [One Unit, Two Counters]

 

A Twin Counter Mode has been added to enable using two counters with only one unit.

*Only two-stage models.

 

Replaceable Front Panel [Design Flexibility]

 

Replace the front panel with an Optional Front Panel to change the basic color from black to light gray or white.

• Optional Front Panels let you match the color of the panel or surrounding devices.

 

H7CX-A Features 14

Waterproof, Dust-proof Structure (UL508 Type 4X and IP66) [Design Flexibility]

 

Worry-free application is possible in locations subject to water.

*When the Y92S-29 Waterproof Packing is used.

 

H7CX-A Features 15

More Complete Tachometer Functionality

H7CX-AW[]

A Wide Range of Input Modes

New input modes have been added to the new models.
Now you can handle a wider range of applications.

 

(1) One-input measurement
Measurement operation with one input.
Select the HI-LO, AREA, HI-HI, or LO-LO output mode.

(2) Independent Measurement for Two Inputs
Measurement operation with two independent inputs.

 

H7CX-A Features 19

 

(3) Differential Input for Two Inputs
Measuring the difference between two inputs (CP1 – CP2).

 

H7CX-A Features 20

 

(4) Absolute Ratio for Two Inputs
Measuring the ratio between two inputs (CP1/CP2).

(5) Error Ratio between Two Inputs
Measuring the ratio between two inputs ((CP1-CP2)/CP2)).

Many Other Useful Functions

• Peak/Bottom Displays
• Output Hysteresis
• Output OFF delay
• Switching the measurement method (pulse cycle/pulse width)
• Startup time
• Auto-zero time
• Averaging method, number of averaging times
• Prescaling
• Decimal point position
• AMD-compatible mode

ModelsH7CX-A114[]-NH7CX-A11[]-NH7CX-A4[]-N
ClassificationPreset counter
Configuration1-stage preset counter, 1-stage preset counter with total counter (selectable) *1
RatingsPower supply
voltage*2
• 100 to 240 VAC, 50/60 Hz
• 24 VAC, 50/60 Hz or 12 to 24 VDC
• 100 to 240 VAC, 50/60 Hz
• 12 to 24 VDC
Operating voltage
fluctuation range
85% to 110% of rated supply voltage (12 to 24 VDC: 90% to 110%)
Power
consumption
Approx. 9.4 VA at 100 to 240 VAC, Approx. 7.2 VA/4.7 W at 24 VAC/12 to 24 VDC, Approx.
3.7 W at 12 to 24 VDC
Mounting methodFlush mounting or surface mountingFlush mounting
External connections11-pin socketScrew terminals
Degree of protectionIEC IP66, UL508 Type 4X (indoors) for panel surface only and only when Y92S-29
Waterproof Packing is used.
Input signalsCP1, CP2, reset, and total reset
CounterMaximum
counting speed
30 Hz (minimum pulse width: 16.7 ms) or 10 kHz (minimum pulse width: 0.05 ms)
(selectable) (ON/OFF ratio 1:1) *Common setting for CP1 and CP2
Input modeIncrement, decrement, increment/decrement (UP/DOWN A (command input), UP/DOWN
B (individual inputs), or UP/DOWN C (quadrature inputs))
Output modeN, F, C, R, K-1, P, Q, A, K-2, D, and L.
One-shot output
time
0.01 to 99.99 s
Reset systemExternal (minimum reset signal width: 1 ms or 20 ms, selectable), manual, and
automatic reset (internal according to C, R, P, and Q mode operation)
TachometerRefer to the separate table for tachometer function ratings.
Prescaling functionYes (0.001 to 9.999)Yes (0.001 to 99.999)Yes (0.001 to 9.999)
Decimal point adjustmentYes (rightmost 3 digits)
Sensor waiting time290 ms max. (Control output is turned OFF and no input is accepted during sensor
waiting time.)
Input methodNo-voltage (NPN) input/voltage (PNP) input (switchable)
No-voltage inputs:
ON impedance: 1 kΩ max. (Leakage current: 12 mA at 0 Ω)
ON residual voltage: 3 V max.
OFF impedance: 100 kΩ min.
Voltage input:
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
External power supply12 VDC (±10%), 100 mA (except for H7CX-A[]D models) Refer to on page for details.
Control outputContact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1), Minimum applied load:
10 mA at 5 VDC (failure level: P, reference value)
Transistor output: NPN open collector, 100 mA at 30 VDC, Residual voltage: 1.5 VDC
max. (approx. 1 V), Leakage current: 0.1 mA max.
Display*37-segment, negative
transmissive LCD
Character height
Count value: 12 mm (red)
Set value: 6 mm (green)
7-segment, negative
transmissive LCD
Character height
Count value: 10 mm (red)
Set value: 6 mm (green)
7-segment, negative
transmissive LCD
Character height
Count value: 12 mm (red,
green, or orange selectable)
Set value: 6 mm (green)
Digits4 digits
-999 to 9999
(-3 digits to +4 digits)
6 digits
-99999 to 999999
(-5 digits to +6 digits)
4 digits
-999 to 9999
(-3 digits to +4 digits)
Memory backupEEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Operating temperature
range
-10 to 55°C (-10 to 50°C if Counter/Tachometers are mounted side by side) (with no
icing or condensation)
Storage temperature range-25 to 70°C (with no icing or condensation)
Operating humidity range25% to 85%
Case colorBlack (N1.5) (Optional Front Panels are available to change the Front Panel color to light
gray or white.)
AttachmentsFlush mounting adapter,
waterproof packing,
terminal cover

 

 

ModelsH7CX-A[]-NH7CX-A4W[]-NH7CX-AW[]-N/-AU[]-N
ClassificationPreset counterPreset counter/tachometer
Configuration1-stage preset counter,
1-stage preset counter with
total counter (selectable) *1
1-stage/2-stage preset
counter, total and preset
counter *1, batch counter,
dual counter, and twin
counter (selectable)
1-stage/2-stage preset
counter, total and preset
counter *1, batch counter,
dual counter, twin counter,
and tachometer (selectable)
RatingsPower supply
voltage*2
• 100 to 240 VAC, 50/60 Hz
• 12 to 24 VDC
• 100 to 240 VAC at 50/
60 Hz
• 24 VAC at 50/60 Hz or
12 to 24 VDC
• 12 to 24 VDC
Operating voltage
fluctuation range
85% to 110% of rated supply voltage (12 to 24 VDC: 90% to 110%)
Power
consumption
Approx. 9.4 VA at 100 to 240 VAC, Approx. 7.2 VA/4.7 W at 24 VAC/12 to 24 VDC, Approx.
3.7 W at 12 to 24 VDC
Mounting methodFlush mounting
External connectionsScrew terminals
Degree of protectionIEC IP66, UL508 Type 4X (indoors) for panel surface only and only when Y92S-29
Waterproof Packing is used.
Input signalsCP1, CP2, reset, and total
reset
CP1, CP2, reset 1, and reset 2
CounterMaximum
counting speed
30 Hz (minimum pulse width: 16.7 ms) or 10 kHz (minimum pulse width: 0.05 ms)
(selectable) (ON/OFF ratio 1:1) *Common setting for CP1 and CP2
Input modeIncrement, decrement, increment/decrement (UP/DOWN A (command input), UP/DOWN
B (individual inputs), or UP/DOWN C (quadrature inputs))
Output modeN, F, C, R, K-1, P, Q, A, K-2,
D, and L.
N, F, C, R, K-1, P, Q, A, K-2, D, L, and H.
One-shot output
time
0.01 to 99.99 s
Reset systemExternal (minimum reset signal width: 1 ms or 20 ms, selectable), manual, and
automatic reset (internal according to C, R, P, and Q mode operation)
TachometerRefer to the separate table for tachometer function ratings.
Prescaling functionYes (0.001 to 99.999)Yes (0.001 to 9.999)Yes (0.001 to 99.999)
Decimal point adjustmentYes (rightmost 3 digits)
Sensor waiting time290 ms max. (Control output is turned OFF and no input is accepted during sensor
waiting time.)
Input methodNo-voltage (NPN) input/voltage (PNP) input (switchable)
No-voltage inputs:
ON impedance: 1 kΩ max. (Leakage current: 12 mA at 0 Ω)
ON residual voltage: 3 V max.
OFF impedance: 100 kΩ min.
Voltage input:
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
External power supply12 VDC (±10%), 100 mA (except for H7CX-A[]D models) Refer to on page for details.
Control outputContact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1), Minimum applied load:
10 mA at 5 VDC (failure level: P, reference value)
Transistor output: NPN open collector, 100 mA at 30 VDC, Residual voltage: 1.5 VDC
max. (approx. 1 V), Leakage current: 0.1 mA max.
Display*37-segment, negative
transmissive LCD
Character height
Count value: 10 mm (red,
green, or orange selectable)
Set value: 6 mm (green)
7-segment, negative
transmissive LCD
Character height
Count value: 12 mm (red,
green, or orange selectable)
Set value: 6 mm (green)
7-segment, negative
transmissive LCD
Character height
Count value: 10 mm (red,
green, or orange selectable)
Set value: 6 mm (green)
Digits6 digits
-99999 to 999999
(-5 digits to +6 digits)
4 digits
-999 to 9999
(-3 digits to +4 digits)
6 digits
-99999 to 999999
(-5 digits to +6 digits),
tachometer: 0 to 999999
Memory backupEEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Operating temperature
range
-10 to 55°C (-10 to 50°C if Counter/Tachometers are mounted side by side) (with no
icing or condensation)
Storage temperature range-25 to 70°C (with no icing or condensation)
Operating humidity range25% to 85%
Case colorBlack (N1.5) (Optional Front Panels are available to change the Front Panel color to light
gray or white.)
AttachmentsFlush mounting adapter, waterproof packing, terminal
cover
Flush mounting adapter,
waterproof packing,
terminal cover, label for
DIP switch settings

 

*1. 1-stage preset counter and total counter functionality.
*2. Do not use the output from an inverter as the power supply.The ripple must be 20% maximum for DC power.
*3. The display is lit only when the power is ON. Nothing is displayed when power is OFF.

Tachometer Function Ratings

 

ModelH7CX-A114[]-N
H7CX-A11[]-N
H7CX-A4[]-N
H7CX-A[]-N
H7CX-A4W[]-N
H7CX-AW[]-N/-AU[]-N
Input modeNo tachometer
functionality
Selectable from independent measurements for 1 or 2 inputs, differential input
for 2 inputs, absolute ratio for 2 inputs, and error ratio for 2 inputs.
Pulse
measurement
method
Periodic measurementPulse width measurement
Maximum
counting
speed
30 Hz
(minimum
pulse width:
16.7 ms)
1-input mode: 10 kHz
(minimum pulse width:
0.05 ms)
Other modes: 5 kHz
(minimum pulse width:
0.1 ms)
30 Hz
(minimum
pulse
width:
16.7 ms)
1-input mode: 10 kHz
(minimum pulse width:
0.05 ms)
Other modes: 5 kHz
(minimum pulse width:
0.1 ms)
Minimum input
signal width
30 ms *11-input mode: 0.2 ms
Other modes: 0.4 ms *
Measuring
ranges
0.001 to
30.00 Hz
1-input mode: 0.001 to 10
kHz,
Other modes: 0.01 to 5
kHz
0.030 to
999999 s
1-input mode: 0.0002 to
99999 s
Other modes: 0.0004 to
99999 s
Sampling period200 ms min.200 ms min. or continuous
selectable (minimum
interval of 10 ms)
Continuous (minimum interval of 10
ms)
Measuring
accuracy
±0.1% FS ±1 digit max. (at 23 ±5°C)
Output modeInput mode:
Not 2-input independent measurement: HI-LO, AREA, HI-HI, LO-LO
2-input independent measurement: HI-HI, LO-LO
Auto-zero time0.1 to 999.9s
Startup time0.0 to 99.9s
AveragingSimple averaging/moving averaging selectable, Processing: OFF, 2, 4, 8, or 16
times
Hold inputMinimum input signal width: 20 ms

* An input OFF time of at least 20 ms is required.

 

Characteristics

 

Insulation resistance100 MΩ min. (at 500 VDC) between current-carrying terminals and exposed non-current-
carrying metal parts, and between non-continuous contacts
Dielectric strength2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-
carrying metal parts
2,000 VAC, 50/60 Hz for 1 min between power supply and input circuit for all models
except H7CX-[]D[] (1,000 VAC for 24 VAC/12 to 24 VDC)
1,000 VAC (for H7CX-[]SD[]), 50/60 Hz for 1 min between control output, power supply,
and input circuit (2,000 VAC for models other than H7CX-[]SD[])
1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts
Impulse withstand voltage3.0 kV between power terminals (1.0 kV for models with 24 VAC/12 to 24 VDC or 12 to 24
VDC)
4.5 kV between current-carrying terminals and exposed non-current-carrying metal parts
(1.5 kV for models with 24 VAC/12 to 24 VDC or 12 to 24 VDC)
Noise immunity±1.5 kV between power terminals (±480 V for models with 12 to 24 VDC) ±600 V
between input terminals Square-wave noise by noise simulator (pulse width: 100 ns/1 μs,
1-ns rise)
Static immunityMalfunction: 8 kV Destruction: 15 kV
Vibration
resistance
Destruction10 to 55 Hz with 0.75-mm single amplitude each in three directions for 2 h each
Malfunction10 to 55 Hz with 0.35-mm single amplitude each in three directions for 10 min each
Shock
re-sistance
Destruction300 m/s2 each in three directions
Malfunction100 m/s2 each in three directions
Life expectancyMechanical: 10,000,000 operations min.
Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load, ambient temperature
condition: 23°C) *
WeightApprox. 130 g (Counter only)

* Refer to the Life-test Curve.

 

Life-test Curve (Reference Values)

Resistive load

H7CX-A Specifications 7

Inductive load

H7CX-A Specifications 8

A current of 0.15 A max. can be switched at 125 VDC (cosφ=1) and current of 0.1 A max. can be switched if L/R=7 ms. In both cases, a life of 100,000 operations can be expected.

Applicable Standards

 

Approved
safety
standards
cULus (or cURus): UL508/CSA C22.2 No. 14 *1
EN 61010-1 (IEC 61010-1): Pollution degree 2/overvoltage category II
B300 PILOT DUTY
1/4 HP 120 VAC, 1/3 HP, 240 VAC, 3 A resistive load
VDE0106/P100 (finger protection)
EMC(EMI) EN61326-1 *2
Emission Enclosure: EN 55011 Group 1 class A
Emission AC mains: EN 55011 Group 1 class A
(EMS) EN61326-1 *2
Immunity ESD: EN 61000-4-2: 4 kV contact discharge; 8 kV air discharge
Immunity RF-interference: EN 61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz); 10 V/m (Pulse-
modulated, 900 MHz ±5 MHz)
Immunity Conducted Disturbance: EN 61000-4-6: 10 V (0.15 to 80 MHz)
Immunity Burst: EN 61000-4-4: 2 kV power-line; 1 kV I/O signal-line
Immunity Surge: EN 61000-4-5: 1 kV line to lines (power and output lines); 2 kV line to ground (power and
output lines)
Immunity Voltage Dip/Interruption: EN 61000-4-11: 0.5 cycle, 100% (rated voltage)

 

*1. The following safety standards apply to models with sockets (H7CX-A11[] or H7CX-A114[]).
cUL (Listing): Applicable when an OMRON P2CF(-E) Socket is used.
cUR (Recognition): Applicable when any other socket is used.
*2. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)

I/O Functions

Using as a Counter *1

 

InputsCP1, CP2(1) In general (except for Dual Counter Mode)
Reads counting signals.
Increment, decrement, command, individual, and quadrature inputs accepted.
(2) When used as a dual counter or twin counter
Reads CP1 count signals with CP1 input and CP2 count signals with CP2 input.
Increment signals can be input.
Reset/reset 1(1) In general (except for Dual Counter Mode)
Resets present value and outputs (OUT2 when using the batch counter) *2.
Counting cannot be performed during reset/reset 1 input.
Reset indicator is lit while reset input is ON.
(2) When used as a dual counter or twin counter.
Resets the CP1 present value (to 0).
Counting for CP1 input cannot be performed while the reset 1 input is ON.
The reset indicator is lit while the reset 1 input is ON.
Total reset or reset 2The reset function depends on the selected configuration *3.
OutputsOUT1, OUT2Outputs signals according to the specified output mode when a set value is reached.

 

 

*1. For information on operation of I/O functions, refer to Catalog.
*2. In increment mode or increment/decrement mode, the present value returns to 0; in decrement mode, the present
value returns to the set value with 1-stage models, and returns to set value 2 with 2-stage models.
*3. Reset operates as described in the following table. (The reset indicator will not be lit.)
ConfigurationReset operation
1-stage/2-stage preset counterDoes not operate (not used).
Total and preset counterResets the total count value.
The total count value is held at 0 while the total reset input is ON.
Batch counterResets the batch count value and batch output (OUT1).
The batch count value is held at 0 while the reset 2 input is ON.
Dual counterResets the CP2 present value.
Counting for CP2 input cannot be performed while the reset 2 input is ON.
Twin counterResets the CP2 present value.

 

• The following table shows the delay from when the reset signal is input until the output is turned OFF. (Reference values)

Minimum reset signal widthOutput delay time
1 ms0.8 to 1.2 ms
20 ms15 to 25 ms

 

Operating Procedures (Tachometer Function)

 

InputsCP1, CP2Reads counting signals. (The CP2 input can be used when the input mode is not 1-input
mode.)
Reset/reset 1Holds the measurement value and outputs. (The reset 2 input can be used when the input
mode is 2-input independent measurement.)
Functions as a hold input.
The measurement value (displayed value) and the outputs are held while the RST Key on the
front panel is pressed.
The reset indicator is lit when the value is being held.
OutputsOUT1, OUT2Outputs signals according to the specified output mode when a set value is reached.

 