Omron timer counter
SKU: H5CX-L8D-N
Specifications
CATEGORY:
PRODUCT BRAND:
PRODUCT NAME:
Omron timer counter
PRODUCT NUMBER:
H5CX-L8D-N
AVAILABILITY:
On-Demand
DESCRIPTION
Rated supply voltage | 24 VAC (50/60 Hz) 12 to 24 VDC (Ripple 20% max.) | |
---|---|---|
Operating voltage range | 85% to 110% of rated supply voltage (90% to 110% at 12 to24 VDC) | |
Power consumption | Approx. 5.1 VA/Approx. 2.4 W | |
Time ranges(Number of ranges) | 10 | |
Time ranges | 0.001 to 9.999 s 0.01 to 99.99 s 0.1 to 999.9 s 1 to 9999 s 0.1 to 999.9 min 1 to 9999 min 0.1 to 999.9 h 1 to 9999 h 1 s to 99 min 59 s 1 min to 99 h 59 min | |
Input method | No-voltage input | |
No-voltage input | Solid state input | Short-circuit (ON) impedance: 1 kΩ max. (Leakage current (0 Ω): Approx. 12 mA) Short-circuit (ON) residual voltage: 3 V max. Open circuit impedance: 100 kΩ min. (The DC voltage must be 30 VDC max.) |
Contact input | Use contact which can adequately switch 5 mA at 10 V | |
Applicable two-wire sensor | Leakage current: 1.5 mA max. Switching capacities: 5 mA min. Residual voltage: 3.0 VDC max. Operating voltage: 10 VDC | |
Output modes | A: Signal ON delay (Ⅰ) A-1:Signal ON delay (Ⅱ) A-2: Power ON delay (Ⅰ) A-3: Power ON delay (Ⅱ) b: Repeat cycle (Ⅰ) b-1: Repeat cycle (Ⅱ) d: Signal OFF delay E: Interval F: Cumulative Z: ON/OFF-duty adjustable flicker S: Stopwatch toff: Flicker OFF start (Ⅰ) ton: Flicker ON start (Ⅰ) toff-1: Flicker OFF start (Ⅱ) ton-1: Flicker ON start (Ⅱ) | |
Control output (Contact output) | Time-limit contact: SPDT Resistive load: 5 A at 250 VAC/30 VDC (cosφ = 1) Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value) | |
Reset system | Power reset (depending on output mode)/Automatic reset (depending on output mode)/External reset/Manual reset | |
Power reset | Minimum power-opening time: 0.5 s (except for A-3, b-1, F, ton-1 and toff-1 mode) | |
Timer mode | Elapsed time (UP) and remaining time (DOWN) (selectable) | |
Display method | 7-segment negative transmissive LCD 4 digit | |
Character height | Present value: 12 mm (Red) Set value: 6 mm (green) | |
Key protect method | Key protect Switch | |
Memory backup method | EEP-ROM (number of writes: 100,000 operations min., Service life: 10 years min.) | |
Ambient temperature (Operating) | -10 to 55 ℃ (with no freezing or condensation) When mount timer side by side: -10 to 50 ℃ (with no freezing or condensation) | |
Ambient temperature (Storage) | -25 to 70 ℃ (with no freezing or condensation) | |
Ambient humidity (Operating) | 25 to 85% | |
Accuracy of operating time | Power-ON start: ±0.01% ±0.05 s max. (The values are based on the set value.) Signal start: ±0.005% ±0.03 s max. (The values are based on the set value.) | |
Setting error | Power-ON start: ±0.01% ±0.05 s max. (The values are based on the set value.) Signal start: ±0.005% ±0.03 s max. (The values are based on the set value.) | |
Influence of voltage | Power-ON start: ±0.01% ±0.05 s max. (The values are based on the set value.) Signal start: ±0.005% ±0.03 s max. (The values are based on the set value.) | |
Influence of temperature | Power-ON start: ±0.01% ±0.05 s max. (The values are based on the set value.) Signal start: ±0.005% ±0.03 s max. (The values are based on the set value.) | |
Insulation resistance | Between current carrying terminals and exposed non-current carrying metal parts: 100 MΩ min. (at 500 VDC) Between non-continuous contacts: 100 MΩ min. (at 500 VDC) | |
Dielectric strength | Between current carrying metal parts and non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min Between control output, and power supply/input circuit: 2000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1000 VAC 50/60 Hz 1 min | |
Impulse withstand voltage | Between power terminals: 1.0 kV Between current carrying terminals and exposed non-current carrying metal parts: 1.5 kV | |
Noise immunity | Between power terminals: ±1.5 kV Between input terminals: ±600 kV square-wave noise by noise simulator, pulse width: 100 ns/1 µs, 1-ns rise | |
Static immunity | Mulfunction: 8 kV, Destruction: 15 kV | |
Vibration resistance | Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz 0.35 mm single amplitude each in 3 directions for 10 min | |
Shock resistance | Destruction: 300 m/s2, 3 times each in 3 axes each directions Malfunction: 100 m/s2, 3 times each in 6 directions | |
Life expectancy | Electrical: 100,000 operations min. (5 A at 250 VAC resistive load at 1800 operations/h, 23 ℃) Mechanical: 10 million operations min. (under no load at 1,800 operations/h, 23 ℃) | |
Degree of protection | IEC IP66, UL508 Type 4X (indoors) (when using the Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter) | |
Mounting method | Flush mounting / Surface mounting | |
External connection method | 8-pin round socket | |
Case color | Black (Munsell N1.5) | |
Applicable socket | P2CF-08, P2CF-08-E, P3G-08 | |
Accessory (sold separately) | Soft Cover: Y92A-48F1 Hard Cover: Y92A-48 Flush mounting adapter: Y92F-30/Y92F-45/Y92F-38 Waterproof packing: Y92S-29 Replacement Front Panel: Y92P-CXT4S/Y92P-CXT4G/Y92P-CXT4B | |
Weight | Main Unit: Approx. 115 g |
Item reviews
Only logged in customers who have purchased this product may leave a review.
Related products
-
48 x 48 x 83.4 mm, 100 to 240 VAC, Time range 1 s to 5999 s (1 range), Output SPDT, 11-pin round socket
Read more -
Omron Automation and Safety H5S-WB2
Read more -
OMRON H3CR-A8E AC100-240V/DC100-125V 50/60HZ Solid-state Multi-functional Timer (8-pin) NN
Read more -
DILET 70-A – Analogue Timer
Read more -
Multiple Operating Modes and Multiple Time Ranges. DIN 48 x 48-mm Multifunctional Timer.
$1.00 Add to cart
Reviews
There are no reviews yet.